CO2 Air Jacketed Incubators
Manufacturer: Sheldon Manufacturing
Starting at from $7,913.69 Sale $7,518.00
Select a product below and add it to your cart to request a quote.
CO2 Air Jacketed Incubators
Description
SHEL LAB CO2 Incubators
SCO Series - Air Jacketed Units
Ideal for Clinical, Analytical, and General Laboratory Applications
SCO air jacketed CO2 incubators provides an optimized culturing environment with passive humidification, highly stable CO2 levels, and tight temperature uniformity to safeguard your cell sample populations.
Features and Benefits
Copper gas plumbing, stainless steel interior, and a glass viewing door gives the SCO5A and SCO10A enhanced protection against microbiological contamination.
Model | SCO5A | SCO10A |
Interior Volume, Nominal | 5 cu ft (142 liters) | 10 cu ft (285 liters) |
---|---|---|
Interior Dimensions, W x D x H | 20.5 x 19.7 x 21.5" (52.1 x 50.0 x 54.6 cm) | 20.5 x 19.7 x 21.5" (52.1 x 50.0 x 54.6 cm) |
Exterior Dimensions, W x D x H | 27.3 x 28.5 x 37.8" (69.3 x 72.4 x 96.0 cm) | 27.3 x 28.5 x 75.5" (69.3 x 72.4 x 191.7 cm) |
Interior Construction | 300 series stainless steel | 300 series stainless steel |
Exterior Construction | 20 gauge steel, powder coated | 20 gauge steel, powder coated |
Shelves | 3 standard, 8 total | 6 standard, 16 total |
Maximum Weight per Shelf | 35 lbs (15.8 kg) | 35 lbs (15.8 kg) |
Permitted Total Load | 105 lbs (47.6 kg) | 105 lbs (47.6 kg) |
Electrical | 50/60Hz, AC | 50/60Hz, AC |
Voltage | 110V-120V | 110V-120V |
Full Load Amps | 6.0 | 12.0 |
Nominal Power (watts @37°C) | 105 | 210 |
Recommended Breaker, Amps | 15 | 15 |
Plug Supplied | NEMA5-15P | NEMA5-15P |
CO2 Range | 1-20% | 1-20% |
Recovery CO2 at 5% | < 5 minutes | < 5 minutes |
Sensor Type | Infrared | Infrared |
Temperature Uniformity (at 37°C) | ±0.25°C | ±0.25°C |
Humidity Range Passive (Ambient 95%) | 2.0 minutes | 2.0 minutes |
Temperature Range Recovery to 37°C | Yes | Yes |
-
Laboratory equipment, particularly controlled temperature equipment, must help ensure that the environment in which specimens or cell cultures are being studied is safe and contaminant-free, and that, above all, study results are reliable.
-
In the ideal laboratory setting, transferring cell growth samples in and out of incubators would be done without concern about contamination and its potential effect on samples. But until environmental control equipment creates this perfect environment, monitoring contamination and ensuring a clean test environment is critical.