CBF Series CO₂ Incubators with Humidity Regulation
Manufacturer: BINDER
Starting at from $15,359.00 Sale $13,823.10
Select a product below and add it to your cart to request a quote.
CBF Series CO₂ Incubators with Humidity Regulation
Description
The BINDER Series CBF CO2 Incubators with Hot Air Sterilization and Humidity Regulation are safe, reliable, smart, and economical. These incubators contain many benefits and important characteristics that allow them to provide the best performance.
Features:
- Contamination-safe humidification system without water pan
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Hot-air sterilizable CO2 sensor with single-beam infrared technology
- Seamless inner chamber made of stainless steel with flanges as shelf support system
- Fanless interior with Venturi CO2 gas mixing nozzle
- Intuitive touchscreen controller
- Internal data logger, measured values can be read out in open format via USB
- Troubleshooting system with visual and acoustic alarms
- Interfaces: Ethernet, USB, zero-voltage alarm contact
- Fail-safe CO2 system for protecting the pH of cell cultures
Benefits:
- Safe - cell cultures receive maximum protection against contamination
- Reliable - constant well-being conditions for the cells
- Smart - simple routine cleaning and convenient operation
- Economical - efficient operation without consumables
SKU | Temperature Range | Temperature Fluctuation | Temperature Variation | Humidity Range | CO2 Range |
---|---|---|---|---|---|
9640-0019 | 60°C +6°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 50 - 95 % RH | 0 - 20 % CO2 |
9640-0020 | 60°C +6°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 50 - 95 % RH | 0 - 20 % CO2 |
9640-0017 | 60°C +6°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 50 - 95 % RH | 0 - 20 % CO2 |
9640-0023 | 60°C +6°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 50 - 95 % RH | 0 - 20 % CO2 |
9640-0024 | 60°C +6°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 50 - 95 % RH | 0 - 20 % CO2 |
-
It is imperative to know the technical aspects that are of particular significance when conducting stability testing in accordance with ICH guidelines along with other international or company-specific standards.
-
Oxygen concentration in particular plays a key role in cell growth.
SKU | # of Shelves | Door Recovery Time | Depth | Height | Width | Power Requirement |
---|---|---|---|---|---|---|
9640-0019 | 3 std./6 max. | 6 min | 28.17 in | 34.28 in | 26.79 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0020 | 3 std./6 max. | 6 min | 28.17 in | 34.28 in | 26.79 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0017 | 3 std./6 max. | 6 min | 28.17 in | 34.28 in | 26.79 in | 200-230 V, 50/60 Hz, 10 A |
9640-0023 | 3 std./8 max. | 6 min | 30.93 in | 40.2 in | 29.16 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0024 | 3 std./8 max. | 6 min | 30.93 in | 40.2 in | 29.16 in | 100 - 120 V, 50/60 Hz, 16 A |