CB Series CO₂ Incubators with Heat Sterilizable CO₂ Sensor
Manufacturer: BINDER
Starting at from $10,302.00 Sale $9,271.80
Select a product below and add it to your cart to request a quote.
CB Series CO₂ Incubators with Heat Sterilizable CO₂ Sensor
Description
The BINDER Series CB CO2 Incubators with Hot Air Sterilization and Heat Sterilizable CO2 Sensors are safe, reliable, smart, and economical. These incubators contain many benefits and important characteristics that allow them to provide the best performance.
Features:
- Optimized double-pan humidification system with condensation protection
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Hot-air sterilization CO2 sensor with single-beam infrared technology
- Seamless inner chamber made of stainless steel with flanges as shelf support system
- Fanless interior with Venturi CO2 gas mixing nozzle
- Intuitive touchscreen controller
- Internal data recording, can be read out in open format via USB interface
- Fault diagnosis system with visual and acoustic alarm
- Interfaces: Ethernet, USB, zero-voltage alarm contact
- Fail-safe CO2 system for protecting the pH of cell cultures
Benefits:
- Safe - cell cultures receive maximum protection against contamination
- Reliable - constant well-being conditions for the cells
- Smart - simple routine cleaning and convenient operation
- Economical - efficient operation without consumables
SKU | Temperature Range | Temperature Fluctuation | Temperature Variation | Humidity Range | CO2 Range |
---|---|---|---|---|---|
9640-0007 | 60°C +4°C | ± 0.1 at 37°C | ± 0.3 at 37°C | 90 - 95 % RH | 0 - 20 % CO2 |
9640-0011 | 60°C +4°C | ± 0.1 at 37°C | ± 0.3 at 37°C | 90 - 95 % RH | 0 - 20 % CO2 |
9640-0012 | 60°C +6°C | ± 0.1 at 37°C | ± 0.3 at 37°C | 90 - 95 % RH | 0 - 20 % CO2 |
9640-0015 | 60° +5°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 90 - 95 % RH | 0 - 20 % CO2 |
9640-0016 | 60°C +6°C | ± 0.1 at 37°C | ± 0.4 at 37°C | 90 - 95 % RH | 0 - 20 % CO2 |
CB 056 Data Sheet | Download | |
CB 170 Data Sheet | Download | |
CB 260 Data Sheet | Download | |
BINDER Service | Download |
-
It is imperative to know the technical aspects that are of particular significance when conducting stability testing in accordance with ICH guidelines along with other international or company-specific standards.
-
Oxygen concentration in particular plays a key role in cell growth.
SKU | # of Shelves | Door Recovery Time | Depth | Height | Width | Power Requirement |
---|---|---|---|---|---|---|
9640-0007 | 2 std./3 max. | 5 min | 21.47 in | 26.56 in | 20.8 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0011 | 3 std./6 max. | 5 min | 28.17 in | 34.28 in | 26.79 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0012 | 3 std./6 max. | 5 min | 28.17 in | 34.28 in | 26.79 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0015 | 3 std./8 max. | 5 min | 30.93 in | 40.2 in | 29.16 in | 100 - 120 V, 50/60 Hz, 16 A |
9640-0016 | 3 std./8 max. | 5 min | 30.93 in | 40.2 in | 29.16 in | 100 - 120 V, 50/60 Hz, 16 A |