Laboratory Standards for Fume Hoods and Biosafety Cabinets

Fume Hood and Biosafety Cabinet

Learn how the OSHA Laboratory Standard and NSF/ANSI 49 influence the design and use of a fume hood and a Class II biosafety cabinet in laboratories.

One of the biggest factors in keeping lab professionals safe is ensuring that the fume hood or biosafety cabinet they use meets the standards and requirements of the federal agency Occupational Safety and Health Administration (OSHA) or private organizations such as NSF International and the American National Standards Institute (ANSI).

OSHA 29 CFR 1910.1450 and Fume Hoods

Laboratory Environments

The OSHA Laboratory Standard, formally known as 29 CFR 1910.1450, addresses the handling of hazardous chemicals in laboratories and sets expectations for maintaining laboratory environments that minimize risks and protect workers' health.

At the heart of this standard is the Chemical Hygiene Plan (CHP), a written program that details the procedures, equipment, and work practices designed to protect employees.

Other primary components of the 29 CFR 1910.1450 are employee education and the use of personal protective equipment (PPE). All personnel must be trained on the risks associated with the chemicals they work with and master how to handle them safely. They must also be provided with and wear lab coats, goggles, and other appropriate PPE when handling hazardous substances.

More importantly, the OSHA Laboratory Standard emphasizes the use of fume hoods and outlines specific requirements that manufacturers and laboratories must follow to ensure compliance.

Fume Hood Requirements

PPE is just one line of defense. Engineering controls or physical systems designed to isolate or remove hazards play a critical role in lab safety. Among the most important of these is the fume hood.

Per OSHA's recommendations, a properly functioning hood should meet these requirements:

Face Velocity Icon

Face Velocity

Face velocity refers to the speed of air entering a fume hood through the space between the work surface and the bottom of the sash. Fume hoods must have a face velocity between 60 and 110 feet per minute (fpm) to ensure effective containment without creating turbulent airflow. The air inside the lab should flow in a manner that supports hood performance: smooth, uniform, and without high-velocity drafts or dead zones.

Monitoring Device Icon

Monitoring

Every hood should be equipped with a continuous monitoring device—usually a flow gauge or alarm system—to confirm that airflow is within safe limits before use. If such a system isn't feasible, handling chemicals of unknown toxicity should be avoided, or alternative local exhaust systems should be used.

Maintenance Icon

Maintenance

OSHA recommends evaluating hood performance at the time of installation and then testing it at least every three months. Any changes to the lab's ventilation setup should also prompt a re-evaluation.

Other Factors to Consider Icon

Other Factors to Consider

Users should mind the position of the sash and maintain the designated operating level to achieve proper containment. Additionally, equipment placement matters; bulky or improperly placed items can disrupt airflow and reduce the hood's effectiveness. Keeping the workspace organized and unobstructed is a simple but vital part of fume hood operation.

NSF/ANSI 49 and Biosafety Cabinets

NSF/ANSI 49

Developed through collaboration between NSF International and ANSI, NSF/ANSI 49 adds another layer of protection by establishing equipment design, construction, and performance standards for Class II biosafety cabinets (BSCs). It addresses important parameters, such as airflow dynamics, filtration efficiency, and even ergonomic design, to ensure BSCs are safe to use, effective, and reliable.

Here are the critical aspects NSF/ANSI 49 addresses:

  • Airflow Velocity and Patterns: Specifies how air should flow within the cabinet to safely contain hazardous materials and protect the user and the environment.

  • HEPA Filtration: Requires High-Efficiency Particulate Air (HEPA) filters that trap 99.99% of particles as small as 0.3 microns.

  • Construction Materials: Sets standards for durable, corrosion-resistant materials that are easy to clean.

  • Noise and Vibration Limits: Defines acceptable levels of sound and vibration to create a more comfortable, desirable, and focused working environment for lab personnel.

  • Lighting: Ensures that the lighting inside the BSC is bright and uniform, allowing for clear visibility and precision during lab work.

  • Performance Testing: Includes comprehensive testing (airflow tests, filter checks, and containment evaluations) to confirm the cabinet's ability to protect personnel, the product, and the surrounding environment.

Following these requirements and standards helps labs and manufacturers lower the risks of accidents and keep the people inside lab facilities safe and healthy.

The Lab Depot takes pride in delivering quality ductless hoods manufactured by trusted companies that comply with the standards set by organizations such as OSHA, NSF, and ANSI. For expert support, contact our team at 1-800-733-2522, email, or through live chat on our website.

Request A Quote

Customer Information
Shipping Address
Billing Address

Will you need a lift gate? *

(For deliveries requiring a LTL truck and the customer does not have a dock door)

Would you like to add shipping amount to quote? *

Are you tax exempt? *

(If you are tax exempt, please email your tax exemption form to [email protected])

Upload PDF: