Class II Type A2 Biosafety Cabinets
Manufacturer: Across International
Description
A biosafety cabinet, also called a biological safety cabinet or microbiological safety cabinet, is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.
Features:
- Motorized front glass viewing window with optional foot switch
- UV light with life indicator
- Waterproof in-chamber power sockets
- Large LCD display
- Easy-to-clean stainless steel chamber
- Special treated unit housing with anti-mold and antiseptic coating
- Auto start and stop function (e.g. UV lights)
- Automatic flow speed adjustment
- Mobile base stand can be removed if the user prefers to place it on a table top
- 70% of air is recirculated back into the unit, 30% is exhausted
Steps before and after using a Biosafety Cabinet:
- Step 1: Fully close the front glass panel and turn on the UV light for 30 minutes (you can use the timer setting). Users should leave the room during this disinfection period
- Step 2: Raise the glass panel to the recommended opening height and turn on air circulation for 10 minutes
- After the operation is done, fully close the glass panel and turn on the UV light for another 30 minutes for decontamination.
Important Guidelines:
- No flammable and explosive substances (building up of flammable material may cause an internal fire or explosion)
- No volatile chemicals (may cause damage to HEPA filters to the point where it allows particles to leak through)
- No toxic chemicals or materials (May reach room occupants)
- No open flame (will disrupt airflow patterns) chemicals or materials (may reach room occupants)
- No open flame (will disrupt airflow patterns)
- We recommend using the following for disinfecting the surfaces of a BSC, depending on the agent to be controlled: Sodium hypochlorite (bleach), Ilodophors (Wescodyne), Phenolics (Hilphene, Vespene) and Quaternary ammonium compounds (Conflikt, EndbacII)
- Minimal use (10 mL or less) of decontaminant, such as 70% isopropyl or ethyl alcohol, is allowed
- If gaseous, vaporized, or aerosolized chemicals must be generated in a BSC, you should assure yourself that the quantity being generated will NOT cause a flammable or toxic risk
Certifications:
- NSF certified
| SKU | Includes | Warranty | Air Flow Rate | Compliance | Air Displacement |
|---|---|---|---|---|---|
| BC-2F.110 | HEPA Filter, Foot Switch, & Detachable Stand | 1 Year | 100-110 FPM Inflow, 60-70 FPM Downflow | NSF/ANSI 49 | Positive & Negative |
| BC-3F.110 | HEPA Filter & Foot Switch | 1 Year | 100-110 FPM Inflow, 60-70 FPM Downflow | NSF/ANSI 49 | Positive & Negative |
| BC-4F.110 | HEPA Filter & Foot Switch | 1 Year | 100-110 FPM Inflow, 60-70 FPM Downflow | NSF/ANSI 49 | Positive & Negative |
| BC-6F.110 | HEPA Filter & Foot Switch | 1 Year | 100-110 FPM Inflow, 60-70 FPM Downflow | NSF/ANSI 49 | Positive & Negative |
| SKU | Material | Electrical Information | Dimensions | Lighting |
|---|---|---|---|---|
| BC-2F.110 | 304 Stainless Steel Chamber, Powder Coated Steel Exterior | 100V, 60Hz, 1 PH, 200W | 27.5 in x 25.5 in x 48.5 in | Germicidal UV & LED Lights |
| BC-3F.110 | 304 Stainless Steel Chamber, Powder Coated Steel Exterior | 100V, 60Hz, 1 PH, 400W | 42.8 in x 30.5 in x 89.0 in | Germicidal UV & LED Lights |
| BC-4F.110 | 304 Stainless Steel Chamber, Powder Coated Steel Exterior | 100V, 60Hz, 1 PH, 400W | 54.5 in x 30.5 in x 63.5 in | Germicidal UV & LED Lights |
| BC-6F.110 | 304 Stainless Steel Chamber, Powder Coated Steel Exterior | 100V, 60Hz, 1 PH, 500W | 73.5 in x 30.5 in x 90.5 in | Germicidal UV & LED Lights |
Starting at $5,590.00